Products

Triple/Dual/Single Repeater/Booster

  • 3G 7dBm PICO Home Booster Specification

    Model No. PHB-1800

Specifications

Parameters Specifications
Frequency Range Up Link (RX) 1710 ~ 1725 MHz
Down Link (TX) 1805 ~ 1820 MHz
Frequency Bandwidth 15 MHz
Gain ≧ 60 dB(in-band > 60dB)
Gain Flatness ≦ ± 1.5 dB
(Peak to Peak ≦ -0dB ~ +3dB)
Automatic Gain Control Range (AGC) ≧ 20 dB
Auto Gain Setting 15dB @ 1dB/ Step (Gain : 45~60dB)
Maximum Input Power (Without Damage) 0 dBm (with AGC ON and Full Attenuation)
Output Power Up Link (RX) ≧ 7 dBm / One Carrier (RMS)
≧ 4 dBm / Two Carriers (RMS)
Down Link (TX) ≧ 7 dBm(in-band>7dBm) / One Carrier
≧ 4 dBm / Two Carriers
Automatic Shut Down Power Level (Always Auto Recovery) Up Link (RX) O/P ≧ + 9 dBm / One Carrier
Down Link (TX) O/P ≧ + 9 dBm / One Carrier
Group Delay < 2.5 us
Noise Figure < 6 dB @Max Gain
VSWR ≦ 1.5:1
TX / RX Isolation > 75 dBc
Frequency Stability < ± 0.01 ppm
Out of Band Gain 0.2≦f_offset<1.0 MHz < 60 dB
1.0≦f_offset<5.0 MHz < 45 dB
5.0≦f_offset<10.0 MHz < 45 dB
10.0 MHz≦f_offset < 35 dB
Operating band Unwanted emission 0.015 MHz ≤ f_offset < 0.215 MHz < -14 dBm /RBW13KHz
0.215 MHz≤ f_offset < 1.015 MHz < -14 dBm /RBW13KHz
1.015 MHz ≤ f_offset < 1.5 MHz < -26 dBm /RBW13KHz
1.5 MHz ≤ f_offset < 10.5 MHz < -13 dBm /RBW 1MKHz
10.5 MHz ≤ f_offset < f_offsetmax < -15 dBm /RBW 1MKHz
Spurious Emission -36dBm/RBW 1KHz @ 9 KHz ~ 150 KHz Fully comply With 3GPP TS 36.106 Chapter 9 (Category B )
-36dBm/RBW 10KHz @ 150 KHz ~ 30 MHz
-36dBm/RBW 100Khz @ 30 MHz ~ 1 GHz
-30dBm/RBW 1MHz @ 1 GHz ~ 12.75 GHz
Error Vector Magnitude (EVM) ≤7 % RMS
Adjacent Channel Rejection Ratio (ACRR) ≧ 25dB @± 5 MHz & ±10 MHz
Input Intermodulation Fully comply With 3GPP 36.106
Output Intermodulation Fully comply With 3GPP 36.106
Impedance 50Ω
RF Connectors Single I/P Port SMA type Female Connector
Environment Condition IP30
Power Consumption ≦ 8W
Power Plug Taiwan Type
Power Unit AC (110~220V, 20%)(Plug type--1 round pin and 2 flat pins, Taiwan type) to DC adapter with International Safety Approval (CE, GS, CSA, UL, 3C, NSDFI, …)
PSU have current protection. PSU will automatically shutdown when abnormal current is occuring.
PSU have temperature sensing function.
When temp of PSU or repeater body is over limit, PSU will automatically shutdown and send alarm via RCU board.
Operating Temperature 0 ℃ ~ + 55 ℃
Humidity ≦ 95 %
Cooling Heat sink Convection Cooling
Dimension (H * W * D) 95*185*35mm
Weight ≦ 1Kg
External Donor Ant Gain ≧ 7dBi
External Donor Ant Dimension ≦ 11.3*9.5*2.3 CM
Embedded Service Ant Gain Embedded with Gain as Max 2dBi ( 0 ~ 2dBi)
External Service Output Port Loss 3dB
Material Certificate RoHS
Jumper Cable Loss 10m < 6dB loss
Mean Time Between Failure (MTBF) ≧ 50,000 Hours
Alarm AGC out of range, Auto Isolation Detection
ISO Detection & Auto Gain Setting Periodically check the real ISO and Auto Gain Setting(AGS) after ISO check. Auto Daily Isolation check
Auto Shutdown & Auto Gain Setting System shall auto-shutdown when ISO is not enough. And system can auto-recover by itself until 3 times. Once the lack-isolation status is still there after 3-times-auto-recovery, then system becomes Always-SD until AC RESET
LED Indicators PSU (1pcs Green LED)
UL and DL HPA Failure (1pcs Red LED)
UL and DL Isolation Alarm (1pcs Red LED)
Isolation / Output Level Display (by Green LED)