Triple/Dual/Single Repeater/Booster

  • 3G 40dBm Repeater Specification

    Model No. U-2100X

A. Electrical Specifications 3G

No. Parameters Specifications
1 Frequency Range UL 1945~1960MHz
DL 2135~2150MHz
2 Frequency Bandwidth 15MHz(continuous wave)
3 Repeater Type Band Selective
4 Gain UL ≥85dB(In-Band), (Factory setting on 70dB Gain)
DL ≥90dB(In-Band), (Factory setting on 70dB Gain)
5 Gain Flatness 3 dB Max. p-p (+3/-0dB)(90~93dB Gain)
6 Manual Gain Control (Step Attenuation) ≥30dB @ 1dB/Step
7 Auto Gain Control ≥30dB
8 Gain Trailing Function When DL AGC be activated, booster gain in both DL and UL path shall be
controlled to keep the output level not over Max output level automatically and simultaneously
9 Output Power UL ≥+23dBm @1 channel(tone)
≥+20dBm @2 channels(tones)
DL ≥+40dBm @1 channel(tone)
≥+37dBm @2 channels(tones)
10 Out of Band Gain 2.7≤f_offset≤3.5MHz ≤60dB
3.5≤f_offset≤7.5MHz ≤45dB
7.5≤f_offset≤12.5MHz ≤45dB
12.5MHz≤f_offset ≤35dB
11 Input inter-modulation fully comply with 3GPP 25.106 chapter 11
12 Output inter-modulation fully comply with 3GPP 25.106 chapter 12
13 Spurious and intermodulation fully comply with 3GPP 25.106 chapter 9
14 Tx/Rx Isolation ≥105dBc
15 Error Vector Magnitude (EVM) ≤10% RMS
16 ACRR (Adjacent Channel Rejection Ratio) DL ≥33dB (5MHz & 10MHz)
17 ACRR (Adjacent Channel Rejection Ratio) UL ≥33dB (5MHz & 10MHz)

B. Common Specifications

No. Parameters Specifications
8 Gain Trailing Function When DL AGC be activated, booster gain in both DL and UL path shall be controlled
to keep the output level not over Max output level automatically and simultaneously
1 Noise Figure ≤6dB
2 Return Loss ≤-14dB
3 Group Delay ≤6us
4 RF Connectors N-female
5 Operating Temperature 0~50℃
6 Environment Condition IP55
7 Weight ≤50kg
8 RCU & Antenna combined loss ≤30dB
9 Remote Control Unit Via USB port at local site Via 2/3G modem at remote site
10 Backup battery AC Fail Alarm sending to OMC Server
11 Alarm on the GUI AGC out of range, PA output power alarm, DC power failure, Door open alarm, Temperature alarm
12 Power Unit AC (110~220V, 20%) to DC International Safety Approval (CE, GS, CSA, UL, 3C, NSDFI, …)
PSU should have current protection. PSU will automatically shutdown when abnormal current is occuring.
PSU should have temperature sensing function. When temp of PSU or repeater body is over limit,
PSU should automatically shutdown and send alarm via RCU board.
13 Power Consumption ≤180W
14 Material Certificate RoHS
15 MTBF >50,000 hours
16 LED Indicator PWR LED ( Normal Green / Fail Dark )
PA Fail ( Normal Dark / Fail Green )